Posts Tagged ‘storage’

Solid Glass Calibrations for Liquid Level Gauges

Solid Glass Gauge Tops Now Available:

tank level gauge with glass top

Liquid Level Tank Gauge with more durable solid glass top

 

The new solid glass gauge display offers the same or better physical durability as the original plastic tops. However, this new glass gauge top offers much better resistance to sun damage, heat, weathering, chemical fumes, and more.  

The new glass gauge top eliminates the discoloration and cloudiness that can sometimes occur with the original plastic tops.  

It also will not warp, no matter how much heat and sun you expose it to. 

The new glass calibration will also hold up better when exposed to more aggressive chemical conditions, such as acids, caustics, high ethanol E85, Bio Diesel, etc…  

Currently, this glass option is available on three models.  The Type D At A Glance Direct Reading Gauge, the Type H Therma Gauge, and the Type K At A Glance Leak Gauge.

The oldest most reliable mechanical gauge on the market just got better.  As always, our gauges and all the parts on our gauges are Made in the USA.  

See More Pictures – Click Here

 

Or Visit our Website:

www.ksentry.com

Krueger Gauge News and Events

Trade Shows:

We just wrapped up the Informex Show in Miami, Florida.  I would like to thank everyone that attended our booth.  Our liquid level gauges, designed for above ground storage tanks, are a perfect fit in the volatile world of aggressive chemicals.   Our mechanical gauges are approved for use in flammable liquids, and our all stainless/ all plastic level gauge designs can hold up to nearly any type of corrosive chemical environment.

All Plastic Liquid Level Chemical Gauge

All Stainless Liquid Level Chemical Gauge

We also just finished reserving our booth at the NACS / PEI Show in Las Vegas.  Show dates are from October 8th – 10th 2014.  Our booth number is 6320.  We look forward to seeing all of our old friends at the show, and hopefully making some new ones.

Industy News:

NYC rules for non metallic AST’s

Diesel Generator Leaks. Completely Preventable with the proper gauging.

 

AST Industry News and Articles

Blogged by Lee Geurts

www.ksentry.com

Pennsylvania Aboveground Storage Tank Regulations

Inspectors from the state Department of Environmental Resources are ramping up efforts to find unregistered fuel storage tanks, as one local farmer discovered when he was recently fined by the DEP because he had not obtained a permit for his 8,000-gallon tank.

Why the increased scrutiny?

According to DEP spokesman Kevin Sunday, there was no one specific instance that sparked the agency’s actions to seek out unregistered fuel tanks.

“This is something that the department has been aware of for some time,” Sunday said, “and with the winter months coming up, we wanted to get everyone on board.”

The DEP’s effort, Sunday said, “is to make sure we register both in-ground and above-ground tanks that are not currently registered.”

So in October, DEP sent letters to 1,172 fuel oil providers across the state asking them to help find unregistered tanks. Fuel distributors are required to ask the tank owner to provide a DEP-issued registration certificate before any fuel (gasoline, diesel fuel or kerosene) can be placed in the tank.

“If the distributors deliver product to an unregistered storage tank, they are also liable for any damages” that may occur if fuel escapes from a leaky tank, Sunday said.

If DEP is not aware of unregistered tanks, it cannnot conduct routine inspections on them and the tanks could pose a threat to the environment if the tank or its pipes fail.

Pennsylvania DEP is ramping up it’s AST regulations.
First off, be sure your tank is registered:
Once your tank is registered, you need to be sure that you pass regular inspections.

On page 6 of this last document, references are made to Overfill Prevention Equipment as well as Leak Detection Equipment.  Krueger Sentry Gauge offers inexpensive solutions in both cases.

Lee Geurts

Krueger Sentry Gauge Company

Montana DEQ – Aboveground Storage Tank Inspection

Montana DEQ – Storage Tank Inspection

Is the aboveground storage tank (AST) temporary or permanently removed from Is the aboveground tank protected from vehicle impacts by posts constructed
www.deq.mt.gov/pet/Forms/PDFS/StorageTankCkecklist.pdf

PDF is a check list provided by The Montana DEQ for AST self instpection.

Krueger Sentry Gauge can provide a high level overfill alarm (both visual and audible) to notify the person filling the tank that the fluid has reached 90 percent.  This should satisfy step eleven on the inspection shee.

See example products and documents from our website.

Level Gauge for visual indication

Overfill Alarm for audible indication

PDF for ordering instructions on gauges for the purpose of Overfill alert.

Chemical Spill Contained in Double Wall Tank

DEC Investigates Chemical Spill At LaFargeville Crowley Plant | WWNY TV 7 – News, Weather and Sports for | Watertown, NY | Local News

DEC Investigates Chemical Spill At LaFargeville Crowley Plant

Story Published: Dec 5, 2011 at 6:18 PM EST

Story Updated: Dec 5, 2011 at 6:18 PM EST

According to the New York State Department of Environmental Conservation, 400 gallons of chemicals spilled last week at the Crowley Foods plant in LaFargeville.

No chemicals were released into the environment.

The DEC said it received a report of the spill on December 2.

The following materials leaked:

- Sodium Hydroxide
- Sulfuric Acid
- Nitric Acid

The DEC said two doublewall aboveground storage tanks leaked their chemical product into the secondary containment of their respective tank.

Plant personnel plan to pump product back into the original tanks, use the chemical up, then replace the tanks, the DEC said.

orginal story from : http://www.wwnytv.com/

ReBlogged by Lee Geurts

www.ksentry.com

Double Wall Tanks doing their Job.  Get Chemical Level Gauges / Chemical Tank Gauges from us at Krueger Gauge.

Examples

All Stainless Gauges

All Plastic Gauges

Above Ground Tank Installation- NFPA 30- Tank Storage

The following PDF is the NFPA Code for above ground storage tank (AST) installation.

Above-Ground-Tank-Installation-Relevant-NFPA-Code

On page 4, Section 4.3.2.3.3, letter C the code states the following:

Means shall be provided to prevent overfilling by sounding an alarm when the liquid level in the tank reaches 90 percent of capacity and by automatically stopping delivery of liquid to the tank when the liquid level in the tank reaches 95 percent of capacity. In no case shall these provisions restrict or interfere with the proper functioning of the normal vent or the emergency vent

Our Overfill alarms, when mounted to our standard liquid level gauge (Therma Gauge), provide a 110 DB alarm to warn that the tank is reaching capacity.  The following documents provide testing results and ordering info:

In cases where liquids are flammable and fire protection is paramount, adding the Glass Calibration and the Aluminum Lock Nut to the gauge should eliminate the plastic from the gauge and provide a glass and metal barrier between the inside of the tank and the outside.  For additional protection, upgrade the Aluminum Nut to the Gauge Guard.

Already have a Krueger Gauge and want to get it up to code.  If the gauge is fully functional, just order our upgraded Fire Protection Gauge Repair Kit  and an overfill alarm.  In the case of the kit, we will need to know what gauge type you have.  Example part number is (-”gauge type”-Kit-GLC-ALN). Both the kit and the alarm are easily retrofitted to existing Krueger Tank Gauges.